Sign In | Join Free | My himfr.com
Home > OLT XPON Board >

HUAWEI CQ1 SL91 4-Port Channelized STM-1 For Huawei Interface Board

Changsha Xingheda Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap HUAWEI CQ1 SL91 4-Port Channelized STM-1 For Huawei Interface Board from wholesalers
     
    Buy cheap HUAWEI CQ1 SL91 4-Port Channelized STM-1 For Huawei Interface Board from wholesalers
    • Buy cheap HUAWEI CQ1 SL91 4-Port Channelized STM-1 For Huawei Interface Board from wholesalers

    HUAWEI CQ1 SL91 4-Port Channelized STM-1 For Huawei Interface Board

    Ask Lasest Price
    Brand Name : HUAWEI
    Model Number : CQ1
    Price : $100-$200
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 500pcs/week
    Delivery Time : 3-7 work days
    • Product Details
    • Company Profile

    HUAWEI CQ1 SL91 4-Port Channelized STM-1 For Huawei Interface Board

    HUAWEI CQ1 SL91 4-port channelized STM-1 for Huawei interface board


    Product Description:

    The functional version of CQ1 boards is SL91.


    Application:

    CQ1 boards apply to OptiX RTN 910 NEs to transparently transmit STM-1 services over packet radio networks. CQ1 boards receive/transmit only channelized STM-1 services.


    CQ1 boards are used in the following scenarios:

    STM-1 services are transparently transmitted over packet radio networks.

    Multiprotocol Label Switching (MPLS) tunnels traverse a TDM network.

    Circuit emulation service (CES) E1 services are converged to channelized STM-1s.

    Transparently Transmitting STM-1 Services over Packet Radio Networks

    Figure 1 Application scenario of CQ1 boards (1)

    Carrying MPLS Tunnels over a TDM Network

    Figure 2 Application scenario of CQ1 boards (2)

    Converging CES E1 Services to Channelized STM-1s

    Figure 3 Application scenario of CQ1 boards (3)


    NOTE:

    The IF boards shown in Figure 1 to Figure 3 must be general-purpose IF boards or cross polarization interference cancellation (XPIC) IF boards working in native E1+Ethernet or native STM-1+Ethernet mode.


    Functions and Features:

    CQ1 boards receive and transmit four channels of channelized STM-1 optical/electrical signals.


    Table 1 lists the functions and features supported by CQ1 boards.

    Table 1 Functions and features that CQ1 boards support.

    Function and FeatureDescription
    Basic functionsReceives and transmits four channels of channelized STM-1 optical/electrical signals.
    Supported packet service types

    Circuit emulation service (CES) E1

    ML-PPP E1

    Port specificationsOptical ports

    Use small form-factor pluggable (SFP) optical modules and support optical ports of the Ie-1, S-1.1, L-1.1, and L-1.2 types.

    Comply with ITU-T G.957.

    Electrical ports

    Use SFP electrical modules.

    Comply with ITU-T G.703.

    Fractional E1Transparently transmits 64 kbit/s CES services.
    CESMaximum number of services80
    Encapsulation mode

    CESoPSN (CESoPSN stands for circuit emulation services over packet switch networks)

    SAToP (SAToP stands for Structure-Agnostic Time Division Multiplexing over Packet)

    Idle timeslot compressionSupported only in CESoPSN mode
    Jitter buffering time (us)875 to 16,000
    Packet loading time (us)125 to 5,000
    CES ACR(ACR stands for adaptive clock recovery)Supported, but the NE can only function as a master node
    Transparent transmission of SDH overheadsSupported
    ML-PPPType of links carrying ML-PPP linksE1s in channelized STM-1s
    Maximum number of supported PPP links252
    Maximum number of supported ML-PPP groups32
    Maximum number of links in one ML-PPP group16
    ClockClock source

    Each line port provides one channel of SDH line clock signals.

    Each board supports two channels of E1 clock signals over its STM-1 ports.

    Clock protection

    Protection implemented by providing clock sources with different priorities

    Protection implemented by running Synchronization Status Message (SSM) protocol

    Protection implemented by running extended SSM protocol

    SDH line clock retimingSupported
    Linear multiplex section protection (MSP)1:1 linear MSP
    DCNOutband DCNEach SDH line port can provide one data communications channel (DCC) that is composed of three DCC bytes, nine DCC bytes, or 12 DCC bytes.
    Inband DCNTransmits DCN information over ML-PPP links.
    Operation and maintenanceLoopback

    Supports inloops at STM-1 ports.

    Supports outloops at STM-1 ports.

    Supports inloops over E1 channels.

    Supports outloops over E1 channels.

    Warm and cold resettingSupported
    Switching a laser on or offSupported
    Manufacturer information queryingSupported
    Power consumption queryingSupported
    SFP module information detecting and queryingSupported

    Working Principle and Signal Flow:

    This section describes how the function units of a CQ1 board process channelized STM-1 optical signals.

    Function Block Diagram

    Figure 1 CQ1 board function block diagram

    Signal Processing in the Receive Direction

    Table 1 Signal processing in the receive direction of a CQ1 board

    StepFunction UnitProcessing Flow
    1Signal interface unit

    Receives channelized STM-1 signals.

    Regenerates STM-1 optical signals.

    Checks for R_LOS alarms.

    Converts STM-1 optical signals into STM-1 electrical signals.

    2SDH processing unit

    Restores clock signals.

    Synchronizes frames and checks for R_LOS and R_LOF alarms.

    Descrambles signals.

    Checks B1 and B2 bytes and generates alarms and performance events, if any.

    Checks the M1 byte and bits 6-8 of the K2 byte, and generates alarms and performance events, if any.

    Checks for changes in Synchronization Status Messages (SSMs) in the S1 byte and reports the SSM status to the system control and communication unit.

    Extracts orderwire bytes, auxiliary channel bytes (including F1 and serial bytes), DCC bytes, and K bytes, and transmits the bytes to the logic processing unit.

    Adjusts AU pointers and generates performance events, if any.

    Checks higher order path overheads and generates alarms and performance events, if any.

    Decapsulates E1 signals from the STM-1 signals.

    3Packet processing unit

    Frames E1 signals.

    Performs CES emulation.

    Performs Multilink Point-to-Point Protocol (MP-PPP) processing.

    Encapsulates PWE3 services and converts them into Ethernet services.

    4Logic processing unit

    Grooms services from service buses to the GE bus on the backplane.

    Sends service signals to the packet switching unit.


    Signal Processing in the Transmit Direction:

    Table 2 Signal processing in the transmit direction of a CQ1 board

    StepFunction UnitProcessing Flow
    1Logic processing unit

    Receives service signals from the packet switching unit.

    Grooms services from the GE bus on the backplane to service buses.

    2Packet processing unit

    Decapsulates service signals.

    Restructures CES packets.

    Converts signals into E1 signals and sends the E1 signals to the SDH processing unit.

    3SDH processing unit

    Multiplexes E1 signals into STM-1 signals.

    Sets higher order path overheads.

    Sets AU pointers.

    Sets multiplex section overhead bytes.

    Sets regenerator section overhead bytes.

    Scrambles signals.

    4Signal interface unitConverts electrical signals into optical signals.

    Control Signal Processing:

    The CQ1 board is directly controlled by a CPU on the system control and communication unit. The CPU issues configuration and query commands to other units of the board over the control bus. These units send command responses, alarms, and performance events to the CPU unit over the control bus.

    The logic control unit decodes the address read/write signals from the CPU.

    Power Supply Unit

    The power supply unit receives two -48 V power supplies from the backplane. It then converts the -48 V power supplies into +3.3 V power and supplies the +3.3 V power to other units on the board.

    Clock Unit


    The clock unit performs the following operations:

    Extracts line clock signals or E1 clock signals and transmits them to the system control and communication unit.

    Receives system clock signals from the control bus on the backplane and supplies clock signals to other units on the board.


    Front Panel:

    A CQ1 board has indicators and STM-1 ports on its front panel.

    Front Panel Diagram

    Figure 1 Front panel of a CQ1 board providing optical ports

    Figure 2 Front panel of a CQ1 board providing electrical ports


    If you are interested, please let us know the specific model. We will provide the best service and the best price!




    Pr

    Product Tags:

    HUAWEI CQ1

      

    HUAWEI CQ1 SL91

      

    CQ1 SL91

      
    Quality HUAWEI CQ1 SL91 4-Port Channelized STM-1 For Huawei Interface Board for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Changsha Xingheda Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)